HY4840 Tracking Index Tester
Test on the insulated material surface, apply certain voltage between size of 2mm×5mm platinum electrodes for 30 secs, then drip conducting liquid (0.1%NH₄CL) in the height of 35mm, to test the tracking resistance of the solid insulated material under humid surrounding and electric field. It can also test CTI and PTI.
Product Information
Brand:
Anytester
Model number:
HY4840
Test on the insulated material surface, apply a certain voltage between 2mm×5mm platinum electrodes for 30 seconds, then drip a conducting liquid (0.1% NH₄Cl) at a height of 35mm to test the tracking resistance of the solid insulated material under a humid environment and electric field. It can also test CTI and PTI. This instrument complies with the following international and industry standards. IEC: IEC 60112. Using a digital instrument control system and imported control components. The fixture is made of high-quality stainless steel, corrosion-resistant and rust-free. One-button timing device for convenient equipment use and simple operation. Advanced temperature control and temperature measurement system make the test more accurate and the results more reliable. Tempered glass observation window allows observation of the entire test process. Technical Specification: Technical Specification Model: HY4840 Electrode size: (2mm ± 0.1mm) × (5mm ± 0.1mm) × (40mm ± 5mm), 30°±2° Electrode distance: 4.0mm ± 0.01mm Electrode force: 1.00N±0.001N Test voltage: 100V~1000V Droplet height: 35mm ± 5mm (Adjustable) Droplet time: 30s±0.1s (Adjustable) Number of droplets: 1 ~ 9999 Test voltage: 100~1000V Tracking adjustment: 0.50A ±10% 2.00s±10% Alarm Exhaust pore size: Φ100mm Dimensions: 1120×520×1020mm Power supply: 220V 0.6kVA 50-60Hz
Recommended products
ASTM D1895 Apparent Density Tester
AT303 ASTM Series Apparent Density Tester is used to measure the apparent density, bulk factor, and where applicable, the pourability of plastic materials such as molding powders. The apparatus consists of a measuring cup and a funnel. These series testers conform to ASTM D1895.
TST-300 Congo Red Thermal Stability Tester
TST-300 Congo Red Thermal Stability Tester is used to determine the thermal stability of PVC compounds for insulating and sheathing materials of electric cables.
Dial Type Plastic Charpy Impact Tester
HY4251A Charpy Impact Tester is used to determine the impact toughness of non-metallic materials such as rigid plastics, fiber-reinforced composite materials, nylon, glass, ceramics, cast stone, asbestos boards, electrical insulating materials, etc. It is suitable for notched and unnotched specimens.
HY4900 Torque Rheometer
HY4900 Torque Rheometer is a measuring system for studying the flow, plasticizing, heat and shear stability of polymers. This system consists of a platform and some function units, such as the mixer and extruder. The platform connected with a function unit can measure flow and compounding behaviors, critical processing parameters of temperature, pressure, torque and viscosity of polymers in the laboratory—requiring only small sample volume. This instrument, which is designed as an excellent system with high measuring precision, handling flexibility and testing reproducibility, has been widely applied in scientific research, quality control and process experiment.